{"product_id":"deif-lsu-112dg-load-sharing-paralleling-and-operation-unit","title":"Deif lsu-112dg load sharing paralleling and operation unit","description":"\u003ctable style=\"border-collapse: collapse; font-size: 14px; width: 100.036%; height: 568.4px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: rgb(242, 242, 242); height: 19.6px;\"\u003e\n\u003cth style=\"border: 1px solid black; padding: 8px; width: 22.3128%; height: 19.6px;\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"border: 1px solid black; padding: 8px; width: 71.5196%; height: 19.6px;\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"border: 1px solid black; padding: 8px; width: 22.3128%; height: 19.6px;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid black; padding: 8px; width: 71.5196%; height: 19.6px;\"\u003eDEIF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"border: 1px solid black; padding: 8px; width: 22.3128%; height: 19.6px;\"\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid black; padding: 8px; width: 71.5196%; height: 19.6px;\"\u003eUni-line\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"border: 1px solid black; padding: 8px; width: 22.3128%; height: 19.6px;\"\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid black; padding: 8px; width: 71.5196%; height: 19.6px;\"\u003eLoad Sharing, Paralleling \u0026amp; Operation Unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"border: 1px solid black; padding: 8px; width: 22.3128%; height: 19.6px;\"\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid black; padding: 8px; width: 71.5196%; height: 19.6px;\"\u003eLSU-112DG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"border: 1px solid black; padding: 8px; width: 22.3128%; height: 39.2px;\"\u003e\u003cstrong\u003eMeasured Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid black; padding: 8px; width: 71.5196%; height: 39.2px;\"\u003e415 V (Module: 415 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"border: 1px solid black; padding: 8px; width: 22.3128%; height: 39.2px;\"\u003e\u003cstrong\u003eUL\/cUL Max Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid black; padding: 8px; width: 71.5196%; height: 39.2px;\"\u003eMax. 450 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"border: 1px solid black; padding: 8px; width: 22.3128%; height: 39.2px;\"\u003e\u003cstrong\u003eMeasured Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid black; padding: 8px; width: 71.5196%; height: 39.2px;\"\u003e0.56 A (Module: 0.6 A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"border: 1px solid black; padding: 8px; width: 22.3128%; height: 19.6px;\"\u003e\u003cstrong\u003eMeasured Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid black; padding: 8px; width: 71.5196%; height: 19.6px;\"\u003e320 W (Scale: 0.93)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"border: 1px solid black; padding: 8px; width: 22.3128%; height: 19.6px;\"\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid black; padding: 8px; width: 71.5196%; height: 19.6px;\"\u003e230 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"border: 1px solid black; padding: 8px; width: 22.3128%; height: 39.2px;\"\u003e\u003cstrong\u003eUL Supply Options\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid black; padding: 8px; width: 71.5196%; height: 39.2px;\"\u003e24 VDC (Class 2) and 110 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"border: 1px solid black; padding: 8px; width: 22.3128%; height: 19.6px;\"\u003e\u003cstrong\u003eCoupling\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid black; padding: 8px; width: 71.5196%; height: 19.6px;\"\u003e1W3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"border: 1px solid black; padding: 8px; width: 22.3128%; height: 19.6px;\"\u003e\u003cstrong\u003eRelay Outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid black; padding: 8px; width: 71.5196%; height: 19.6px;\"\u003eMax. 250 VAC or 24 VDC, 8 A (Resistive)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"border: 1px solid black; padding: 8px; width: 22.3128%; height: 19.6px;\"\u003e\u003cstrong\u003eAnalog Outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid black; padding: 8px; width: 71.5196%; height: 19.6px;\"\u003eMax. 10 V (if available)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"border: 1px solid black; padding: 8px; width: 22.3128%; height: 39.2px;\"\u003e\u003cstrong\u003ePower Factor (Cos φ)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid black; padding: 8px; width: 71.5196%; height: 39.2px;\"\u003e0.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"border: 1px solid black; padding: 8px; width: 22.3128%; height: 39.2px;\"\u003e\u003cstrong\u003eLoad Change Delay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid black; padding: 8px; width: 71.5196%; height: 39.2px;\"\u003e\u0026gt;5% change with 10 seconds delay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"border: 1px solid black; padding: 8px; width: 22.3128%; height: 19.6px;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid black; padding: 8px; width: 71.5196%; height: 19.6px;\"\u003e600 V CAT III\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"border: 1px solid black; padding: 8px; width: 22.3128%; height: 19.6px;\"\u003e\u003cstrong\u003eProtection Class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid black; padding: 8px; width: 71.5196%; height: 19.6px;\"\u003eType 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"border: 1px solid black; padding: 8px; width: 22.3128%; height: 39.2px;\"\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid black; padding: 8px; width: 71.5196%; height: 39.2px;\"\u003eControls load sharing and paralleling of generators for stable operation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"border: 1px solid black; padding: 8px; width: 22.3128%; height: 39.2px;\"\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid black; padding: 8px; width: 71.5196%; height: 39.2px;\"\u003eGenerator control systems, marine power systems, industrial power management\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"border: 1px solid black; padding: 8px; width: 22.3128%; height: 19.6px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid black; padding: 8px; width: 71.5196%; height: 19.6px;\"\u003e790 gm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe DEIF LSU-112DG Load Sharing, Paralleling \u0026amp; Operation Unit from the Uni-line series is basically an advanced control module that helps you manage and optimize the operation of multiple generators in parallel. Developed by DEIF, a globally recognized leader in power management and marine automation, this unit makes sure the load is distributed efficiently, keeps synchronization stable, and ensures reliable generator operation in complex power systems.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eEngineered to handle 415V measurement voltage and run on a 230V AC supply, the LSU-112DG is ideal for applications that require precise monitoring and control of electrical parameters like voltage, current, and power. With support for relay outputs (up to 250VAC \/ 24VDC, 8A) and optional analog outputs (up to 10V), the unit offers flexible integration into modern control systems.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e \u003c\/p\u003e\n\u003ch2 class=\"MsoNormal\"\u003e\u003cb\u003eApplications : \u003c\/b\u003e\u003c\/h2\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e1. Generator Load Sharing Systems : \u003c\/b\u003eThe unit ensures equal load distribution among multiple generators for efficient operation.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e2. Marine Power Management Systems : \u003c\/b\u003eIt controls and synchronizes generators on ships for stable onboard power supply.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e3. Industrial Power Plants : \u003c\/b\u003eUsed to manage parallel generator operations in industrial power systems.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e4. Switchgear and Control Panels : \u003c\/b\u003eIntegrates into panels to provide monitoring and control of generator performance.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e5. Backup and Emergency Power Systems : \u003c\/b\u003eEnsures reliable power sharing during backup power operations.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e6. Maintenance and Replacement Applications : \u003c\/b\u003eIdeal for upgrading or replacing existing load sharing modules.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e \u003c\/p\u003e\n\u003ch2 class=\"MsoNormal\"\u003e\u003cb\u003eFeatures : \u003c\/b\u003e\u003c\/h2\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e1. Ensures Balanced Load Distribution in Generator Systems : \u003c\/b\u003eMaintains equal load sharing to prevent generator overload.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e2. Enhances Stability in Marine Power Applications : \u003c\/b\u003eProvides precise synchronization for smooth generator operation onboard.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e3. Supports Reliable Operation in Industrial Power Systems : \u003c\/b\u003eAccurate measurement and control ensure consistent performance.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e4. Improves Efficiency in Power Management Systems : \u003c\/b\u003eOptimizes generator usage and reduces energy waste.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e5. Optimizes Control in Switchgear Applications : \u003c\/b\u003eFlexible relay and analog outputs enable easy system integration.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003e\u003cspan\u003e6. Facilitates Safe Operation in Maintenance Applications : \u003c\/span\u003e\u003c\/b\u003e\u003cspan\u003eBuilt-in delay and protection features enhance system safety.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cdiv id=\"faqs\"\u003e\n\u003ch2\u003eFrequently Asked Questions ( FAQs ) : \u003c\/h2\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e1. What is the DEIF LSU-112DG unit used for?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis unit is used for load sharing, paralleling, and operation control of multiple generators in power systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e2. What is the main function of load sharing?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eLoad sharing ensures equal distribution of electrical load among generators to prevent overload and improve efficiency.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e3. Where is the LSU-112DG commonly used?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt is widely used in marine vessels, industrial power systems, and generator control panels.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e4. What supply voltage does this unit require?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe unit typically operates on a 230V AC supply, with additional UL options available.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e5. What type of outputs does this unit provide?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt provides relay outputs up to 250VAC or 24VDC and optional analog outputs up to 10V.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e6. Can this unit be used in generator synchronization?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, it is designed to synchronize generators and ensure stable parallel operation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e7. What industries use this load sharing unit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIndustries such as marine, power generation, manufacturing, and infrastructure commonly use it.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e8. Why is load sharing important in power systems?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt improves efficiency, prevents generator overload, and ensures a stable and reliable power supply.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Deif","offers":[{"title":"Default Title","offer_id":44375005430019,"sku":"22754","price":308.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0669\/6304\/6659\/products\/20210318_123014_resized.jpg?v=1699304724","url":"https:\/\/aeliyamarinetech.com\/products\/deif-lsu-112dg-load-sharing-paralleling-and-operation-unit","provider":"Aeliya Marine Tech","version":"1.0","type":"link"}