Rosemount 01151-1308 Pressure Transmitters 94V-0 Rosemount Assy: 01151-1308 Pwb 01151-1310-2 Drg No: 01151-1307 00751-0045 Ajaf4115 T0006558
Ae 01151-0685 Pressure Transmitter Gauge 4-20 Ma Ae 01151-0685 0 To 14 Ph
Endress+Hauser Cpm253-pr0010 Transmitter Liquisys-m Ph / Redox (Not Working) Endress+Hauser Liquisys-m Ph / Redox Order Code: Cpm253-pr0010 Meas. Range: Ph0…14 +/-1500Mv Temperature: -50…150°C Output: 0/4…20Ma
Rosemount 5081-t-ht-67 Two Wire Conductivity Transmitter 42.4 Vdc 4-20 Ma Rosemount Emerson Two Wire Model: 5081-t-ht Model: 5081-t-ht-67 Output: 4-20 Ma Supply: 42.4 Vdc Max 9241495-00 Dwg: 1400677
Rosemount Pwb 08732 0921-4 Printed Circuit Board For Transmitter 94V-0 Rosemount Cca 08732-0922 Pwb 08732 0921-4 032780 F09350 Pj21454
Trafag 8202.79.2210 Pressure Transmitter 12–34 Vdc 4–20 Ma Trafag Type: 8202.79.2210 Range: 0…16 Bar-g 0…1,6 Mpa-g 12…34V/4…20Ma Ta: -25…85˚C
Rosemount 2051Cd2F22A1As2B4M5Q4 Output Foundation Fieldbus Pressure Transmitter Rosemount Output Foundation Fieldbus Model: 2051Cd2F22A1As2B4M5Q4 Supply: 9.0-32.0 Vdc, 17.5 Ma
Honeywell 50049713A111 Pressure Transmitter Bp21W16-e1352 Honeywell S971396Sj0H 50049713A111 Bp21W16-e1352
Honeywell 50049713-112 Pressure Transmitter S969340Sj1G Honeywell S969340Sj1G 50049713-112 210201
Rosemount 5081-c-ff Two Wire Fieldbus Transmitter 9-32 Vdc At 22 Ma Rosemount Analytical Inc. Two Wire Model: 5081-c-ff Output: Fieldbus
Honeywell 50049713-115 Pressure Transmitter Honeywell 50049713-115
Vega Br64.Xxgg1Ghkmax Pressure Transmitter 12–36Vdc 4–20Ma 0-10Bar Vega Hart Vegabar 64 Type: Br64.Xxgg1Ghkmax Instrument Specifications: Process Temperature: -20…+120°C Range: 0…10Bar; (0…1000Kpa) Process Pressure: -1…60Bar; (-100…6000Kpa)
Rosemount 8732Emt1A1K1M4 Hart Communication Protocol Magnetic Flow Transmitter Rosemount Hart Communication Protocol Model: 8732Emt1A1K1M4 Supply: 90-250 Vac 50/60Hz, 0.45A, 40 Va Output: 4-20Ma, Pulse 0-10,000 Hz Dekra 14Atex0071 X Ex D Eb [Ia Ga] Iic T6…T3 Gb
Rosemount 03031-0020-3120 Communication Protocol Pressure Transmitter P0027992 Rosemount Hart Communication Protocol 3051 P/N: 03031-0020-3120
Honeywell Hnwg50049849-002 Hart Temperature Transmitter Honeywell Hart P/N: Hnwg50049849-002
Honeywell 50129828-001 Pressure Transmitter Ecn-2022-369 Honeywell P/N: 50129828-001 D/C: Cn24W18-k2132
Honeywell Hnwg50049849-002 Hart Temperature Transmitter Bp22W37-v0390 Honeywell Hart P/N: Hnwg50049849-002
Honeywell Hnwg-50096656-001 Hart Temperature Transmitter Rev.2.000000 Honeywell Hart P/N: Hnwg-50096656-001
Sts Atm Pressure Transmitter 9–33V Dc 4–20 Ma Sts Hirschmann Atm 113992 P: 0…30 Psig Tcomp: 0…70°C
Rosemount 02051-9001-0002 Pressure Transmitter Module I 21.75 Ma E01511 P0245421 Rosemount Hart 2051 Electronics External Zero/Span Adjustments P/N: 02051-9001-0002 Output:  4-20 Ma Std.Alarm/Saturation Levels Low Alarm: I 3.75 Ma
M-system Ab-aa-r Pressure Transmitter Display Only 4-20Ma Dc M-system Co. Ltd. Analog Backup Station Model: Ab-aa-r Input: 4-20Ma Dc (250 Ohm) Out: 4-20Ma Dc
Honeywell Hns50086423-002 Hart Temperature Transmitter Rev. A Honeywell Scc Hart P/N: Hns50086423-002 50087660-001 Rev. A 152878
M-system M3Svs-4Wa-r Signal Transmitter 4-20Ma Dc 24V Dc N4359A M-system Signal Transmitter Model: M3Svs Model: M3Svs-4Wa-r Input: -10-10V Dc
Rosemount 03031-0193-0103 Pressure Transmitter Display Only Rosemount P/N: 03031-0193-0103 Label: 3031-622-1/A